← Back to home

Contributions

Designed mounts for off-the-shelf inline fans to mix warm argon in print chamber

Requirement: System must support 3 kg of weight. Any supports must be kept airtight from outside environments. Design must be removable. System must avoid position limits of the print table.

Result: Fans were mounted without failures. Fans operate as intended.

Designed and manufactured ducting containing water-cooled heatsinks.

Requirement: System must cool argon temperatures to around 45C near the print head. Ducting must connect to an air curtain to protect the viewing window. System must avoid critical geometries and leave room for an Infrared Camera system.

drawingVelocity calculation (MATLAB)

Documents

DWGVelocity calculation (MATLAB)
No link